In high-frequency transformer winding, is enamel wire replaceable by triple insulated wire?

YES, In the same specification, the outer diameter of a triple insulated wire is larger than that of an enameled wire. There is no problem with using triple insulated wire instead of enameled wire as long as the bobbin has enough reserve space. Wires that are triple insulated are frequently used in high-frequency transformers that are subject to safety regulations, as they can produce high current densities and a small creepage distance.

阅读更多 »
Uncategorized
Doris Chan

What Is Split Bobbin Transformers?

Generally, bobbin transformers are two-winding transformers in which the primary and secondary coils are wound side by side on separate bobbin separated by an insulating barrier to create a two-winding transformer.

阅读更多 »
Uncategorized
Doris Chan

What Are The Losses Of Transformers In Operation?

Among the transformer losses there are iron losses, copper losses, hysteresis losses, eddy current losses, stray losses, dielectric losses, and other types of losses. In transformers, hysteresis losses are caused by changes in the magnetic field of the transformer core, whereas copper losses are caused by the resistance of the transformer windings.