7 Ways To Reduce High-Frequency Transformer Leakage

A high-frequency transformer is commonly used in a wide range of electronic applications, such as power supplies, audio equipment, and telecommunications systems. During operation, alternating current is used to induce a voltage in a secondary coil, which is then used to power other devices or equipment.

Despite their widespread use, high-frequency transformers can be prone to leakage, which is the unwanted release of magnetic fields into the surrounding environment. This can lead to a number of problems, including electromagnetic interference (EMI), reduced efficiency, and even safety issues.

Reducing leakage in high-frequency transformers is therefore critical to ensuring their proper functioning and avoiding these problems. In this blog, we will explore seven ways to reduce leakage in high-frequency transformers, including decreasing winding distance, using shielding material, selecting the right core material, using symmetrical layouts, lowering the frequency, using multiple layers of windings, and choosing the right wire gauge. By implementing these methods, you can ensure that your high-frequency transformer operates efficiently and effectively, while also minimizing its impact on the surrounding environment.

1.Decrease Winding Distance

Winding distance refers to the distance between the primary and secondary windings of a transformer. When the winding distance is large, there is more space for magnetic flux to leak out of the transformer. This results in increased leakage inductance, which is a measure of the amount of flux that leaks out of the transformer.

Leakage inductance causes several problems in a transformer. Firstly, it reduces the efficiency of the transformer by increasing the amount of power that is lost as heat. Secondly, it can cause voltage spikes and ringing in the output, which can damage the connected circuits. Lastly, it can reduce the accuracy of the transformer’s voltage regulation.

Below methods for decreasing winding distance for your reference:

  • Use a multi-layer winding configuration: By using multiple layers of windings, the winding distance can be reduced, and the leakage inductance can be decreased.
  • Use a bifilar winding configuration: In a bifilar winding, two wires are wound together in close proximity. This reduces the winding distance and decreases the amount of leakage inductance.
  • Use interleaved windings: Interleaved windings involve alternating layers of primary and secondary windings. This reduces the winding distance and can help to reduce leakage inductance.
  • Use a toroidal core: A toroidal core is a circular-shaped core that allows the windings to be wound more tightly, reducing the winding distance and leakage inductance.
  • Use a bobbin with a smaller diameter: By using a bobbin with a smaller diameter, the windings can be wound more tightly, reducing the winding distance and leakage inductance.
  • Increase the number of turns in the windings: By increasing the number of turns in the windings, the winding distance can be reduced, and the leakage inductance can be decreased.
  • Use a higher permeability core material: A higher permeability core material allows the magnetic flux to be concentrated more tightly, reducing the amount of flux that leaks out of the transformer and decreasing the amount of leakage inductance.

2.Use Shielding Material

Shielding material is used in high-frequency transformers to reduce the amount of magnetic flux that leaks out of the transformer. Magnetic flux is the magnetic field that is generated by the current flowing through the transformer’s windings. When the magnetic flux leaks out of the transformer, it can cause interference with other electronic circuits in the vicinity of the transformer.

Shielding material works by providing a barrier between the transformer’s windings and the surrounding environment. This barrier is typically made of a ferromagnetic material, such as iron or steel, which has a high permeability. When the magnetic flux from the transformer encounters the shielding material, it is absorbed by the material and redirected back into the transformer’s core, where it can be used to generate the output voltage.

By reducing the amount of magnetic flux that leaks out of the transformer, shielding material can improve the efficiency and accuracy of the transformer. It can also reduce the amount of interference that the transformer produces, which can improve the performance of other electronic circuits in the vicinity of the transformer.

Types of shielding material that can be used are as follows:

  • Magnetic shielding tape: Magnetic shielding tape is a flexible, self-adhesive tape made of a thin layer of ferromagnetic material, such as iron or steel. In order to prevent magnetic flux from entering the transformer, it can easily be wrapped around its windings.
  • Mu-metal: Mu-metal is a type of alloy designed for use as a magnetic shield. It has a high permeability and absorbs magnetic flux highly effectively. Mu-metal is typically used to make shielding cans, which are enclosed metal containers placed around the transformer’s windings.
  • Powdered iron: Powdered iron is a ferromagnetic material used to make cores for high-frequency transformers. It can also be used as a shielding material by mixing it with a binder. It can then be formed into a shape that can be placed around the transformer’s windings.
  • Ferrite: Ferrite is a type of ceramic material with high permeability and is used as a core material in high-frequency transformers. It can also be used as a shielding material by forming it into a shape that can be placed around the transformer’s windings.
  • Silicon steel: Silicon steel is a type of electrical steel used to make transformer cores. It has high permeability and can be used as a shielding material by forming it into a shape that can be placed around the transformer’s windings.

3.Select the Right Core Material

The core material is a critical component in high-frequency transformers as it aaffects performance,efficiency, and leakage. The core material is responsible for conducting the magnetic flux that is produced by the transformer’s primary winding to the secondary winding. When the core material conducts magnetic flux efficiently, it helps reduce the leakage of the transformer.

The core material affects the leakage of a high-frequency transformer through its magnetic permeability, which is the ability of a material to conduct magnetic flux. By having a high magnetic permeability, the core material can conduct more magnetic flux and minimize leakage. On the other hand, a low magnetic permeability increases the leakage of the transformer.

Therefore, selecting the right core material with high magnetic permeability is crucial to reduce high-frequency transformer leakage.

The following are examples of core material can be used:

  • Iron core: Iron is the most commonly used core material in high-frequency transformers. It has a high magnetic permeability, which makes it an excellent magnetic flux conductor. However, the iron core material is not suitable for high-frequency transformers above 20kHz.
  • Ferrite core: Ferrite is a ceramic material that has a high magnetic permeability and is suitable for high-frequency transformers that operate above 20kHz. Ferrite cores are popular in high-frequency transformers due to their low cost, high resistance to temperature, and high saturation levels.
  • Amorphous metal core: Amorphous metal cores are made of a ribbon-like material that is created by rapidly cooling molten metal. They have a high magnetic permeability and are suitable for high-frequency transformers that operate above 100kHz. Amorphous metal cores have low core loss and are more energy-efficient than other core materials.
  • Nanocrystalline core: Nanocrystalline cores are made of a ribbon-like material that contains nanocrystals. They have a high magnetic permeability and are suitable for high-frequency transformers that operate above 50kHz. Nanocrystalline cores have low core loss and high saturation levels, which makes them ideal for high-power applications.
  • Tape wound core: Tape wound cores are made of thin metal tape wound into a spiral. They have a high magnetic permeability and are suitable for high-frequency transformers above 20kHz. Tape wound cores have low core loss and are more energy-efficient than other core materials.

4.Use Symmetrical Layouts

Symmetrical layouts are essential in high-frequency transformers as they reduce magnetic flux leakage. A symmetrical layout means that the primary and secondary windings are placed symmetrically around the core. This arrangement helps reduce the magnetic field produced by the primary winding that escapes and induces a voltage in the nearby conductors, leading to leakage.

When the primary and secondary windings are placed symmetrically around the core, the magnetic field produced by the primary winding is cancelled out, reducing the amount of magnetic flux leakage. A symmetrical layout also helps reduce the parasitic capacitance between the windings, which can lead to voltage spikes and high-frequency noise.

Symmetrical layouts are especially important in high-frequency transformers as they operate at high frequencies, where even small amounts of magnetic flux leakage can have a significant impact on the transformer’s performance.

Examples of symmetrical layouts include:

  • Bobbin winding: In a bobbin winding layout, the primary and secondary windings are wound on a plastic or ceramic bobbin, with the core inserted in the middle. The bobbin winding layout ensures that the windings are placed symmetrically around the core, reducing magnetic flux leakage.
  • Toroidal winding: In a toroidal winding layout, the primary and secondary windings are wound on a toroidal core, with the windings placed symmetrically around the core. The toroidal winding layout is popular in high-frequency transformers as itreducesf magnetic flux leakage and parasitic capacitance.
  • Pancake winding: In a pancake winding layout, the primary and secondary windings are wound on a flat or pancake-shaped core, with the windings placed symmetrically around the core. The pancake winding layout is popular in low-profile transformers, sucas powerer supplies and lighting applications.
  • Interleaved winding: In an interleaved winding layout, the primary and secondary windings are interleaved or interwoven on the same core. The interleaved winding layout helps reduce magnetic flux leakage and parasitic capacitance, improving the transformer’s efficiency and reducing high-frequency noise.

5.Lower the Frequency

The leakage in a high-frequency transformer is caused by the magneticfield betweenn the primary and secondary windings. The magnetic field is created by the alternating current (AC) flowing through the primary winding, which induces a current in the secondary winding. However, not all of the magnetic flux generated by the primary winding is coupled to the secondary winding, and some of it leaks into the surrounding air or other materials, causing a loss of energy.

The amount of magnetic flux that leaks out of the transformer is directly related to the frequency of the AC input. Specifically, at higher frequencies, the magnetic field has less time to build up and collapse, resulting in a weaker magnetic coupling between the primary and secondary windings. This weaker coupling allows more of the magnetic flux to leak out of the transformer, resulting in increased leakage.

Benefits and drawbacks of lowering frequency include:

a.Benefits of lowering frequency:

  • Reduced leakage: As discussed above, lowering the AC input frequency can reduce leakage in a high-frequency transformer. This reduction in leakage can improve transformer efficiency and reliability.
  • Reduced core loss: Lowering the frequency can also reduce the core loss in the transformer, which is the energy dissipated as heat within the transformer’s magnetic core. This reduction in core loss can help to extend the life of the transformer.
  • Reduced noise: Lowering the frequency can also reduce the noise generated by the transformer, as the lower frequency reduces the vibrations and oscillations in the transformer’s windings.

b.Drawbacks of lowering frequency:

  • Increased size and weight: Lowering the frequency requires an increase inthe transformer’s size and weight,, as the lower frequency requires a larger core and more turns in the winding.
  • Reduced efficiency: Lowering the frequency can reduce the transformer’s efficiency, as the lower frequency requires more current to achieve the same output power. This increased current can result in higher transformer losses.
  • Reduced power density: Lowering the frequency can also reduce the power density of the transformer, which is the amount of power that can be delivered per unit volume or weight of the transformer. This reduction in power density can limit the applicationof the transformer.

6.Use Multiple Layers of Windings

Multiple layers of windings can reduce leakage in high-frequency transformers by creating a more tightly wound structure that minimizes the space between the windings. This reduces the amount of flux that escapes from the core and is lost through leakage.

The additional layers of windings also help to distribute the voltage and current across the entire transformer. This reduces the likelihood of concentrated areas of high voltage or current that can cause arcing and contribute to leakage. In addition, the increased number of turns of wire in the windings can create a stronger magnetic field. This can improve the overall efficiency of the transformer.

Examples of how to implement multiple layers of windings include:

  • Implementing multiple layers of windings involves winding the transformer with multiple coils of wire, one on top of the other, with insulation layers between them. Here are a few examples of how to implement multiple layers of windings.
  • Disc winding: In disc winding, each layer of wire is wound in a circular pattern around the transformer core, with insulation between each layer. This technique creates a compact, cylindrical winding that is ideal for high-frequency transformers where space is limited.
  • Interleaved winding: In interleaved winding, two or more wires are wound simultaneously around the transformer core, with insulation between them. This technique creates a more complex winding pattern, but it can help to distribute the voltage and current more evenly across the transformer and reduce leakage.

7.Choose the Right Wire Gauge

The wire gauge of a transformer winding casignificantly affecton leakage. High resistance can be created if the wire gauge is too small for the amount of current flowing through the transformer. Thisat causes the wire to heat up and expand. This expansion can cause the winding to loosen, creating gaps where the magnetic flux can escape and contribute to leakage.

On the other hand, if the wire gauge is too large for the amount of current flowing through the transformer, it can create an unnecessary amount of space between the windings, which can also contribute to leakage. Choosing the right wire gauge is therefore critical to reducing leakage and improving transformer efficiency.

To choose the right wire gauge for a transformer winding, there are several factors to consider as follow:

  • Current: The amount of current flowing through the transformer winding will determine the minimum wire gauge required to handle the load without overheating. A general rule of thumb is to choose a wire gauge that can handle at least 125% of the expected current.
  • Voltage: The transformer winding voltage will also affect the wire gauge required. Higher voltages will require thicker wire gauges to prevent arcing and ensure safety.
  • Frequency: The frequency of the transformer’s operation will also affect the wire gauge required. Higher frequencies will require thinner wire gauges to minimize the skin effect, which can increase resistance and cause heating.
  • Space limitations: The amount of space available for the transformer winding will also affect the wire gauge required. Thicker wire gauges may not fit in smaller transformers, so thinner gauges may be necessary.
  • Efficiency: Choosing the right wire gauge can also improve the efficiency of the transformer. A thinner wire gauge can reduce the amount of space between windings, which can reduce leakage and improve efficiency.
  • In conclusion, reducing leakage in high-frequency transformers is crucial to ensuring their proper functioning and avoiding problems such as EMI and reduced efficiency. By implementing the seven methods we have discussed in this blog, you can significantlreduce leakagege in your high-frequency transformer.

To recap, the seven methods for reducing leakage in high-frequency transformers are:

  1. Decrease winding distance
  2. Use shielding material
  3. Select the right core material
  4. Use symmetrical layouts
  5. Lower the frequency
  6. Use multiple layers of windings
  7. Choose the right wire gauge

The effectiveness of these methods may vary depending on the specific application and transformer design. In order to determine what approach is best for your situation, it’s recommended that you consult with a qualified professional.

Leakage reduction in high-frequency transformers is important for both optimal equipment performance and minimizing its impact on the environment. You can enhance the efficiency and effectiveness of your high-frequency transformer by implementing these measures.

Wehope this blog has provided valuablee insights and recommendations for reducing leakage in high-frequency transformers. Implementing these methods will ensure that your equipment operates at its best, while also contributing to a better future.

Share on facebook
Facebook
Share on twitter
Twitter
Share on linkedin
LinkedIn

Leave a Reply

Your email address will not be published. Required fields are marked *

11 + eight =

Ask For A Quick Quote

We will contact you within 1 working day, please pay attention to the email with the suffix “sales@unicreed-transformer.com”